Every term in the wiki, in alphabetical order. BS means it's mainly used in British Standards, NFPA mainly in NFPA codes.

Term Meaning
AFFF Aqueous Film-Forming Foam: foam that spreads a thin film of water over a burning liquid
AHJ NFPA Authority Having Jurisdiction: whoever enforces the code (fire marshal, building official, insurer)
Annex NFPA Explanatory material at the back of an NFPA document. Not mandatory.
BAFE BS UK third-party certification body for fire protection companies (e.g. SP101 for extinguishers)
Basic service BS The annual service of an extinguisher under BS 5306-3
BS / BS EN / BS EN ISO BS British Standard / European standard adopted in the UK / international standard adopted in Europe and the UK
Cartridge-operated Extinguisher pressurised at the moment of use by a separate gas cartridge
Class A, B, C, D, F/K Classes of fire by what is burning. C and F/K differ between BS and NFPA.
Commissioning Checking that a new installation works and is correctly set up before handover
Competent person BS Someone with the training, knowledge and experience to do the job properly
Condemn Permanently remove equipment from service as unsafe or beyond economic repair
CTT DOW Dow's technical requirements documents that apply to work on Dow sites
Discharge test BS Firing an extinguisher to prove it works, as part of the 5-year extended service
Extended service BS Deeper 5-year extinguisher service including a discharge test
FSO / RRO BS Regulatory Reform (Fire Safety) Order 2005, the main fire safety law for workplaces in England & Wales
Fire watch A person or patrol watching an area while its fire protection is impaired
FM Global A US-based industrial insurer that publishes its own engineering "data sheets" and approves equipment ("FM Approved")
Hydrostatic test NFPA Pressure-testing an empty cylinder or shell with water to prove it won't rupture
Impairment Any time a fire protection system is out of service, planned or emergency
Inspection A visual check that equipment is in place, undamaged and appears ready to work
ITM NFPA Inspection, Testing and Maintenance
LOTO Lock-Out / Tag-Out: physically locking and labelling an isolation so nobody can re-energise it
LPCB / LPC Rules BS Loss Prevention Certification Board; the LPC Rules add insurer requirements to BS EN 12845 for sprinklers
Maintenance Work to keep equipment operable or to repair it
Overhaul BS 10-year service of a COβ‚‚ extinguisher including a hydraulic pressure test
Permit to work A written authorisation stating what work may be done, where, how, and under what precautions
Responsible person BS Under the FSO, the person in control of the premises, who has the legal duty for fire safety
Stored pressure Extinguisher permanently pressurised, usually with a gauge
Tamper seal A small plastic tie or seal that breaks if the extinguisher is operated or interfered with
Test Operating equipment to prove it works
UL NFPA Underwriters Laboratories: US product testing and listing ("UL Listed")
Verification-of-service collar NFPA Plastic collar fitted round the valve neck after an internal examination or recharge